What was found
(LOG 4412634) GOUGE ON SKIN AT APPROX 2" AFT OF STA 727F BETWEEN STRINGER 21L AND 22L. DOUBLERS DRILLED UP AND FABRICATED PER SRM 53-00-01-2R-36. TREATED AND PRIMED PARTS. INSTALLED DOUBLER AND TRIPLER PER SRM 53-00-01-2R-36.