What was found
ON ARRIVAL ACS FOUND DAMAGE FWD OF L2 DOOR. FOUND DENT/GOUGE FWD OF L2 DOOR BETWEEN FRAMES 70 AND 72, AND STRINGERS 23L AND 25L. DENT MEASURES 5 INCHES VERTICALLY WITH .5 INCH WIDTH. PERFORMED DVI PER A220 AND TP 51-10-01-01AAA- 018A-A BOTH INTERNALLY AND EXTERNALLY. NO DAMAGED FASTENERS IN VICINITY OF DAMAGE. C/W SECTION 1: TIME LIMITED REPAIR INSTRUCTIONS OF ERA 612109-14, REV ORIG. SECTION 2 TO BE ACCOMPLISHED IN 5 CYCLES AND PERMANENT REPAIR BEFORE 1000 HOURS. FWD TO MONITOR. ASSOCIATED ER/A 14-612109 ADDED FOR AC 8125 COMPLIED WITH PRI 612109-14 REV 0 AND REV 1. COMPLIED WITH FINAL ER/A 612109-14 REV A SECTION III. RII INSPECTIONS COMPLIED WITH. (LP# 4958558)