What was found
GOUGE AND DENT ON FUSELAGE SKIN AT STA 237 BTW LONG 18L-19L. SUMMARY OF NRC 00615: FUSELAGE SKIN AT STA 237 BTW LONG 18L-19L WAS PERMANENT REPAIRED PER B717-200 SRM 53-02-01-2R-1 FIG 202. THE PERMANENT REPAIR SPECIFIED MAINTENANCE REQUIREMENTS ARE A VISUAL INSPECTION INITIALLY WITHIN 8,000 CYCLES AFTER INSTALLATION WITH REPETITIVE INTERVAL OF 8,000 CYCLES, PER B717 SRM 53-02-01-2R-1, PAR 6A. (LP #0167362)