What was found
CREASES WERE FOUND ON REPAIR SKIN SECTION OVER THE FRAME STA 256 BTW LONG 17LH-18LH PER B717 SRM 53-00-01-02 REPAIR 6 PAR. 7. SUMMARY OF NRC 00270: SKIN SECTION OVER THE FRAME STA 256 BTW LONG 17LH-18LH WAS REPAIRED PER B717-200 SRM 53-00-01-2R REP 6. SPECIFIC MAINTENANCE REQUIREMENTS ARE A VISUAL INSPECTION INITIALLY WITHIN 8,000 CYCLES AFTER INSTALLATION WITH REPETITIVE INTERVAL OF 8,000 CYCLES, PER B717 SRM 53-00-01-2R-6, PAR 7A. (LP #0168990)