What was found
SHIP 3236 DISC: ON GROUND AFTER BOARDING, FA'S SMELT FUMES NEAR ROW 24. AFTER TURNING OFF PACKS 1/2 AND BLEED AIR, SMOKE DISSIPPTED. C/A: FOUND SMALL LEAK @ APU OIL PUMP AND OIL CONTAMINATION @ APU INTAKE. C/W A/C CARDS 4900-2001 UP TO AND INCLUDING STEP 4.B., CARDS 2100-2005 AND 0550-9001-A320FAM. (LP: 4545046)