What was found
(LOG 0209318) DURING CAPT WINDSHIELD INSTALLATION LEAK TEST FOUND UPPER OUTBOARD CORNER WINDOW FRAME CRACKED AT INNER RADIUS. REPAIRED CRACK PER ERA 615982-14.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(LOG 0209318) DURING CAPT WINDSHIELD INSTALLATION LEAK TEST FOUND UPPER OUTBOARD CORNER WINDOW FRAME CRACKED AT INNER RADIUS. REPAIRED CRACK PER ERA 615982-14.