What was found
SHIP 699 AFTER REMOVAL CORROSION; STRINGERS (FLOOR STRUCTURE) LBL 2.90 STA 750 WAS FOUND OUT OF LIMITS AT FWD CARGO COMPARTMENT. CORRECTIVE ACTION: FLOOR STRINGERS LBL 2.90 STA 750 WAS REPAIRED PER B757-200 SRM 53-00-53 (0233032)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SHIP 699 AFTER REMOVAL CORROSION; STRINGERS (FLOOR STRUCTURE) LBL 2.90 STA 750 WAS FOUND OUT OF LIMITS AT FWD CARGO COMPARTMENT. CORRECTIVE ACTION: FLOOR STRINGERS LBL 2.90 STA 750 WAS REPAIRED PER B757-200 SRM 53-00-53 (0233032)