SHIP 3127 FOUND BURN IN SKIN BETWEEN FR2 AND FR3 AND BETWEEN STR 32 AND 31. CORRECTIVE ACTION: DRILLED OUT DAMAGE PER A319 SRM 53-11-11. INSTALLED PERMENANT FASTENER PER A319 SRM 53-11-11-300-034. (0235380)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SHIP 3127 FOUND BURN IN SKIN BETWEEN FR2 AND FR3 AND BETWEEN STR 32 AND 31. CORRECTIVE ACTION: DRILLED OUT DAMAGE PER A319 SRM 53-11-11. INSTALLED PERMENANT FASTENER PER A319 SRM 53-11-11-300-034. (0235380)