What was found
DTE, ERA 612138-14, MONITOR INSPECTION LOG REPAIR TO FUSELAGE SKIN REPAIR AT #2 CARGO DOOR OPENING / Y=954 - 994, L-28R IS PENDING DTE STAGE II & III APPROVAL PRIOR TO 12 MONTHS SERVICE FROM 06OCT23. DISCONTINUE REVENUE SERVICE ON OR BEFORE 06OCT24 PENDING STAGE III APPROVAL. ASSOCIATED ERA 00-612138 ADDED FOR AC 9519. **REDEFERRED LOG TO QC, ESTAB MON INSP **. OK TO CLOSE AT ERA 612138-14 REV A. TERMINATED PER LINE 04 LOG COMMENTS. CLOSED LOG AND REMOVED MONITOR INSP PER ALERT 07MAR24 AND LOG COMMENTS. (LP #0004872)