As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON CUSP WEB BTW STA Y986 TO STA Y1000 X=-60 AT CPAX. STRUCTURE WAS MEASURED WITH AN ORIGINAL THICKNESS OF 0.020IN. REMAINING THICKNESS IS 0.005IN THEREFORE REWORKED AREA IS OUT OF LIMITS. SUMMARY OF NRC 00697: CORROSION LEVEL 2. CUSP WEB BTW STA Y986 TO STA Y1000 X=-60 AT CPAX WITH WAS REPAIRED PER B717-200 SRM-53-00-55-2R. (LP #0235916)