What was found
CORROSION ON FLOOR SUPPORT STA Y=160 TO Y=200 X= 6, Y=180 BTW -X=10 TO -X=43, Y= 200 BTW -X=46 TO -X=50 AND Y=200 BTW X=5 TO -X=5 AT PASSENGER CABIN STRUCTURE. SUMMARY OF NRC 00681: CORROSION LEVEL 2. FLOOR SUPPORT STA Y=160 TO Y=200 X= 6, Y=180 BTW -X=10 TO -X=43, Y=200 BTW -X=46 TO -X=50 AND Y=200 BTW X=5 TO -X=5 AT PASSENGER CABIN STRUCTURE WERE FABRICATED PER DWG 9936534 REV BW AND REPLACED PER B717-200 SRM 51-41-02-0G, 51-41-01-0G, AND 51-41-05-0G. (LP #0240010)