As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SHIP 3271 DISC: LT FWD EMERGENCY EXIT HATCH HAS PRESSURIZATION LEAK DURING FCF. C/A: REMOVED EMERGENCY DOOR HATCH LT FWD RE-ACCOMODATED PRESSURIZATION SEAL AND RE INSTALLED EMERGENCY DOOR HATCH ASPER AMM 52-21-11-400-001-A (RESERVOIR LOOKPIN REMOVED) THEN PERFORMED PRESSURIZATION TEST FOR A LEAKAGE OR NOISE AMM 05-53- 00-780-001-A NO LEAK OR NOISE DETECTED RII INSPECTION COMPLETE. (LP: 4339387)