What was found
LH HORT STAB THS LATERAL LOAD FITTING UPPER AND LOWER BUSHING FOUND MIGRATED GAP ONLY. LH HORIZONTAL STABILIZER THS LATERAL LOAD FITTING UPPER AND LOWER LUGS REPAIRED AS PER ER/A 616438-14 PRI REV 0. ER/A 616438-14 PRI REV 0 WORK INSTRUCTIONS COMPARED WITH FINAL ER/A 616438-14 REV ORIGINAL SECTION I WORK INSTRUCTIONS AND FOUND IN COMPLIANCE . REPAIR CLASSIFIED AS CATEGORY B. SECTION I REPAIR HAS STAGE 2 DTA APPROVAL UP TO TOTAL FC OF 38200. CONTACT LIAISON ENGINEERING PRIOR TO THIS THRESHOLD AND OBTAIN STAGE 3 DTA, OR REMOVE THE A/C FROM REVENUE SERVICE AS PER ER/A 616438-14 REV ORIGINAL SECTION II. ASSOCIATED ER/A 14-616438 ADDED FOR AC 3510. (LP# 0253268)