As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SHIP 699 INITIAL INSPECTION (A.A. 5331-01282-03): PREVIOUS REPAIRS (2E/A) ON LAP SPLICE THE REQUIRED INSPECTION AREA ADJACENT TO S-14L BTW FSTA. 580 TO 600, ALSO BTW FSTA. 620 TO 640. CORRECTIVE ACTION: SUMMARY OF NRC 00022: PREVIOUS REPAIR WERE EVALUATED PER ER/A 616137-14AD REV. ORIGINAL SECTION 1: PERMANENT REPAIR AND PRI 616137-14 REV 1. (0274370)