What was found
SHIP 3259 DISC: CONFIRM DT EVALUATION FOR POSSIBLE FCS REPAIR EXTERNAL SKIN LOCATED BT W FR 60 TO FR 61 AND STR 43R TO STR 44 LOWER FUSELAGE (REFERENCE DOC N UMBER A CARD 5100-01821-01A. C/A: PERFORMED ULTRASONIC INSPECTION AND EDDY CURRENT INSPECTION ON EXTERNAL REPAIR LOC. BTW FR60 TO FR61 AND STR 43R TO STR 44 LOWER FUSELAGE AS PER NTM 51-10-15, NTM 51-10-16 AND SRI 53-00-11-205-057 STEP 2.A TABLE 002. CRACK INDICATION NOT FOUND.