What was found
CORROSION ON CLIP STA Y=1072 AND X=-16 LONGERON PROJECTION 18RH AT AFT EMERGENCY EXIT DOOR JAMB AREA. SUMMARY OF NRC 00381: CORROSION LEVEL 2. CLIP (GUSSET) STA Y=1072 AND X=-16 LONGERON PROJECTION 18RH AT AFT EMERGENCY EXIT DOOR JAMB AREA WAS REPLACED PER B717-200 SRM 51-41-05-0G AND 51-41-02-0G. (LP #0314835)