What was found
BIRD STRIKE DAMAGE TO RT HORIZONTAL STAB AT XFS 169.50. OVERALL DENT LENGHTH IS 12 IN LONG BY 7 IN WIDE. SECONDARY DENT IS 2.75 IN LONG BY 2.0 IN WIDE 0.125 DEPTH. THIRD DENT IS 4 IN LONG BY 3 IN WIDE 0.030 IN DEPTH. PERFORMED DAMAGE CONTAINMENT HFEC IAW TOPP 30-10-70 AND MDC93K0393 NDTSPM PART 06 10-01.001. NO DAMAGE INDICATIONS FOUND QC5223 518316. COMPLETED SECTION 1 OF ERA 616472-14 REV ORG PERMENANT REPAIR AFTER 1 CYCLE. INSTALLED PERMANENT REPAIR RT HORIZONTAL STABILIZER LEADING EDGE IAW B717 AMM 55-12-01 PER ER/A 6164472-14 REV ORIG. THIS COMPLETES TERMINATING ACTION. PLEASE CLOSE LOG. CLOSED LOG AND REMOVED MONITOR INSP. (LP #5334026)