As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING EMERGENCY LIGHTS CHECK, THE EXTERIOR EMERGENCY LIGHTS TURN ON WITH FLIGHT CABIN SWITCH IN ARM POSITION. SUMMARY OF NRC00627: CONTINUITY WAS PERFORMED PER B717-200 WDM 33-51-11 IN CONNECTOR (P1-125) OF EMERGENCY EVACUATION BATTERY POWER SUPPLY. A MELTED PIN (F) WAS FOUND AND THE EMERGENCY EVACUATION BATTERY POWER SUPPLY WAS REPLACED PER B717-200 AMM 33-51-06.TEST OK. (LP #0354818)