What was found
EMERGENCY FLOOR LIGHTING DAMAGED OR INOPERATIVE / LOCATIONS:605 / MYCABIN TEXT: FRC335201605 - ADDITIONAL LOCATIONS 606,608 - GREEN MAN EXIT LIGHTS AT DOOR 3L 3R 4R ABOVE 51D AND 51F ALSO IN FA CREW REST AREA STAYS ILLUMINATED ENTIRE FLIGHT. PERFORMED FIM TASK A350-A-33-51-XX-0M001-421A-A REV 68, TESTED EMERGENCY LTS, OPS OK. (LP# 0360818)