What was found
SHIP 3275 DISC: CORROSION SUPPORT FLOOR ANGLE LOCATED AT FR 20 -Y1650 AT FWD GALLEY AR EA. C/A: REPLACED FLOOR ANGLE LOCATED AT FR 20 -Y1650 AT FWD GALLEY AREA AS PER A320 SRM 51-72-11,SRM 51-42-11 AND DWG D53112784 ,ISSUE D , RELEASE DATE 28-MAY-98 .TOOK MEASURE ARE: L=1.958 INCH W=1.298 INCH TOOL USED CALIPER P/N 500-196-30 S/N A22348573 DUE DATE 12 -JUL-24 RII INSPECTION COMPLETE 0855335 AE354QC JOB COMPLETE. (LP: 0374712)