What was found
CORROSION FLOOR SUPPORT -Y1227 AT LEVEL FR67 AT AFT GALLEY AREA ( SSI 534 147). C/A: REPLACED FLOOR SUPPORT -Y1227 AND FASTENERS LOCATED BTW FR66 TO FR68 AFT GALLEY AREA. AS PER A320 SRM 51-42-11 AND SRM 51-72-11, DWG D53472815 SHEET 8 RELEASE DATE: 18-DEC-06 ISSUE: G AND DWG D53472780 SHEET 9 RELEASE DATE:26-APR-18 ISSUE: K. AND TOOK MEASURES OF CORROSION AREA W=0.195 INCH, L=0.281 INCH AND D= 0.027 INCH, RII INSPECTION COMPLETE.