What was found
CORROSION INTERNAL STRUCTURE WEB LOCATED BTW FR69 TO FR70 AT LEVEL STR23R AT AFT GALLEY AREA (SSI 534147). C/A: REPLACED WEB LOCATED BTW FR69 TO FR70 AT LEVEL STR23R AT AFT GALLEY AREA AS PER A320 SRM 51-72-11 AND SRM 51-42-11 AND DWG # D53470100 RELEASE DATE 19-SEP-91 ISSUE U MEASURE OF CORROSION ON SUPPORT WEB ARE : L = 0.510 INCH, W = 0.412 INCH, D = 0.012 INCH. JOB COMPLETE.