What was found
SHIP 3275 DISC: CORROSION FLOOR BEAM +Y1292 LOCATED AT FR 20 AT FWD GALLEY AREA (SSI. 531189 ) C/A: REPLACED FLOOR BEAM Y1292 LOC.BTW FR12 AND FR 24 AT FWD GALLEY AREA AS PER A320 SRM 51-72-11 ,SRM 51-42-11 AND DWG D53110984 , ISSUE :C00, RELEASE DATE : 25-JUN-05 ,DWG D53112812,ISSUE :E00 , RELEASE DATE : 08-JAN-97 AND DWG D53115054 ,ISSUE:D00 , RELEASE DATE :17-MAY-02.TOOK MEASURE OF CORROSION: REMAINDER MATERIAL 0.245 INCH , RII INSPECTION COMPLETE 2243124 JOB COMPLETE. (LP: 0407717)