As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DISBONDED AREAS WERE FOUND ON TRAILING EDGE WEDGE UPPER SKIN OF SLAT 9 AS FOLLOW: 1) 2.0IN LENGTH AND 1.125IN WIDTH AT OSS 600, 2) 0.75IN LENGTH AND 0.6IN WIDTH AT OSS 601 IN REFERENCE TO JOB 206-0001 CARD 5740-01145-05I.. TRAILING EDGE WEDGE UPPER SKIN OF SLAT 9 WAS REPAIRED IAW SRM 51-70-10-2R PROCEDURE REPAIR GENERAL AND SRM 57-43-02-2R PROCEDURE 1 REPAIR 1.