What was found
STR 26L PRODUCTION SPLICE AREA, 1EA FASTENER SHOWS INDICATION WITH VISIBLE DAMAGE TO THE BACKSIDE OF THE STRINGER HOLE-LOCATED FIVE HOLES AFT OF PRODUCTION CUT LINE (MARKED) REF PRI 610260-14 REV 2 STEP 7. SUMMARY SEE NRC 004-0001:10-0653-8-7621/004 00009: COMPLED WITH ER/A 610260-14 REV B. PRI REV. "0", "1", "2", "3", "4", "5", "6", AND "7" REPAIR INSTRUCTIONAL STEPS. ENSURED ALL ER/A 610260-14 REV B PRI REV "0", "1", "2", "3", "4", "5", "6", AND "7" REPAIR INSTRUCTIONAL STEPS ARE COMPLETED AND MATCH FINAL FUSELAGE / EXTERNAL SKIN / BELLY / DENTS ER/A 6010268-14 REV B SECTION I: PERMANENT REPAIR INSTRUCTIONS. (LP #0447074)