Service difficulty report · Power Supply · Boeing 717200

Difficulty date
August 3, 2024
Submitted
August 5, 2024
Operation
Air carrier
Aircraft
N957AT
Make and model
Boeing 717200
Aircraft serial
55019
Aircraft time
55,404 hours, 38,725 cycles
Part
Power Supply
Condition
No Test
Location
Zone 200
Stage of operation
IN
How discovered
C
Nature of condition
L
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING SERVICE CHECK, THE EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE FROM THE FLIGHT ATTENDANT PANEL. MAINTENANCE FOUND THAT THE CABIN EMERGENCY LIGHTS WOULD WORK WITH COCKPIT SWITCH ARMED AND FLIGHT ATTENDANT SWITCH SET TO "ON" ONLY, BUT NOT FROM FLIGHT ATTENDANT PANEL ALONE. CHECKED VOLTAGE GOING TO THE FLIGHT ATTENDANT SWITCH S1-387, ALL TERNMINAL SHOWING 28 VDC. MAINTENANCE REPLACED THE POWER SUPPLY AND BATTERY PACK ASSY B5-125 REF B717 AMM 33-51. OPERATIONAL CHECK WAS GOOD. OK FOR SERVICE. (LP #5718809)