What was found
SHIP 3259 DISC: DTA MONITOR INSPECTION LOG REFERENCE ER/A 597426-14 SECTIONII REQUIRES DTA APPROVAL WITHIN 30,600 CYCLES AFTERSECTION I REPAIR. C/A: DISCONTINUE REVENUE SERVICE WITHIN THE NEXT 30,600 CYCLES AFTER SECTION I REPAIR PENDING A DAMAGE TOLERANCE AND FATIGUE REVIEW. ASSOCIATED ER/A 00-597426 ADDED FOR AC 3259. (LP: 2191353)