As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LH SLAT TRACK NBR 5 HAS EVIDENCE OF CORROSION ON UPPER AFT AND HAS PREVIOUS REWORK, BLEND PER AMDS W/C 5742-010280-02B AND REQUIRES NDT INSPECTION FOR SIGNS OF CRACKS. LH SLAT TRACK NBR 5 UPPER AFT SURFACE BLENDED PER AMDS W/C 5742- 010280-02B PERFORMED HFEC AT BLENDED AREA, NO DEFECTS NOTED. ALL WORK DONE IAW BD500-A-J51-01-20-01AAA-352A-A. (LP# 0544814)