What was found
RH SLAT TRACK NBR 5 HAS EVIDENCE OF CORROSION ON UPPER FWD AND HAS PREVIOUS REWORK, BLEND PER AMDS W/C 5742-010280-02B AND REQUIRES NDT INSPECTION FOR SIGNS OF CRACKS. RH SLAT TRACK NBR5 UPPER FWD SURFACE BLENDED PER AMDS W/C 5742- 010280-02B PERFORMED HFEC AT BLENDED AREA , NO DEFECTS NOTED. ALL WORK DONE IAW BD500-A-J51-01-20-01AAA-352A-A. (LP# 0544835)