As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RH SLAT TRACK NBR5 HAS EVIDENCE OF CORROSION ON UPPER AFT AND HAS PREVIOUS REWORK, BLEND PER AMDS W/C 5742-010280-02B AND REQUIRES NDT INSPECTION FOR SIGNS OF CRACKS. RH SLAT TRACK NBR 5 UPPER AFT SURFACE BLENDED PER AMDS W/C 5742 -010280-02B PERFORMED HFEC AT BLENDED AREA , NO DEFECTS NOTED. ALL WORK DONE IAW BD500-A-J51-01-20-01AAA-352A-A. NO DEFECTS NOTED. (LP# 0544847)