As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LH SLAT TRACK NBR 6 UPPER FWD SURFACE HAS EVIDENCE HAS EVIDENCE OF CORROSION IN ONE AREA AND HAS PREVIOUS REWORK, BLEND PER AMDS W/C 5742-01028-02A AND REQUIRES NDT INSPECTION FOR SIGNS OF CRACKS. BLENDED AREA WITH EVIDENCE OF CORROSION PER AMDS W/C 5742-01028- 02A. WIP 1977594 PERFORMED HFEC AT BLENDED AREA, NO DEFECTS NOTED AND NDT DONE IAW ANDTP BD500-A-J51-01-20-01AAA-353A-A. (LP# 0544885)