What was found
RH SLAT TRACK NBR 6 UPPER AFT SURFACE FOUND WITH CORROSION AND BLENDED PER AMDS W/C 5742-01028-02B, REQUIRES NDT INSPECTION FOR SIGNS OF CRACKS. PERFORMED EDDY CURRENT INSPECTION IAW ANDTP 51-01-20-01AAA- 353A-A NO DEFECTS NOTED. (LP# 0551970)