What was found
LH SLAT TRACK NBR 5 LOWER FD SURFACE REQUIRES NDT INSPECTION PER AMDS W/C 5742-01028-02A. PERFORMED EDDY CURRENT INSPECTION IAW A220 ANDTP BD 500-A-J51-01 -20-01AAA-353A-A. NO CRACKS NOTED. (LP# 0560102)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LH SLAT TRACK NBR 5 LOWER FD SURFACE REQUIRES NDT INSPECTION PER AMDS W/C 5742-01028-02A. PERFORMED EDDY CURRENT INSPECTION IAW A220 ANDTP BD 500-A-J51-01 -20-01AAA-353A-A. NO CRACKS NOTED. (LP# 0560102)