As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR STRUCTURE INTERCOSTAL 12" FORWARD OF FR15 AND AT RBL 28 HAS CORROSION AROUND FASTENER HOLE . -M-. SCEPTRE LOG PAGE ENTERED FOR SDR REPORTING. SUMMARY SEE NR FOR ADDITIONAL INFORMATION 001-0474:5311-2016/004 00448 COMPLIED WITH ER/A 620912-14 PRI REV 0, ER/A 620912-14 PRI REV 1 AND FINAL ER/A 620912-14 REV ORIGINAL. (LP# 0600757)