What was found
(LOG 0631709) CRACK OF 0.625 IN LENGTH ON LH FUSELAGE FRAME AT INBOARD FASTENER HOLE STA. 867 BTW S-8L & S-9L. FRAME STA 867 BTW S-8L & S-9L (REF. CARD 2526-01236-01A, STEP 5) WAS REPAIRED PER ADMS 2526- 01236-02A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(LOG 0631709) CRACK OF 0.625 IN LENGTH ON LH FUSELAGE FRAME AT INBOARD FASTENER HOLE STA. 867 BTW S-8L & S-9L. FRAME STA 867 BTW S-8L & S-9L (REF. CARD 2526-01236-01A, STEP 5) WAS REPAIRED PER ADMS 2526- 01236-02A.