What was found
CORROSION ON FLOOR PANEL STRAP AND WEB (LINES BOTTOM FLOOR PANELS) AT LOWER SILL. SUMMARY OF NRC 00456: CORROSION LEVEL 2. CORROSION ON FLOOR PANEL STRAP AND WEB WAS REMOVED PER B717-200 SRM 51-10-04-0G AND EVALUATED. PANEL STRAP IS WITHIN OF LIMITS BUT WEB IS OUT LIMITS. WEB WAS FABRICATED AND REPLACED PER B717-200 SRM 53-00-00-1A PROCEDURE ALLOWABLE DAMAGE, DWG 9957828 REV AB. (LP #0655708)