Service difficulty report · Duct · Boeing 717200

Difficulty date
October 19, 2024
Submitted
December 9, 2024
Operation
Air carrier
Aircraft
N989AT
Make and model
Boeing 717200
Aircraft serial
55152
Aircraft time
59,705 hours, 42,578 cycles
Engine
Rroyce RB211TRENT76
Part
Duct
Condition
Temp Repair
Location
Zone 400
Stage of operation
IN
How discovered
O
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CRACK ON RIGHT ENG BYPASS DUCT NEAR PRECOOLER INLET WAS TEMPORARILY REPAIRED. RE-INSPECTION REQUIRED PER ER/A 620571-14 REV ORIGINAL. REFER TO LOG #0580374 FOR PRIOR INSPECTION. SECTION 4 INSPECTION MUST BE ACCOMPLISHED BETWEEN 220 AND 180 FLIGHT CYCLES PER ERA 620571-14 REV ORIGINAL. **REDEFERRED LOG TO QC, ESTAB MON INSP BETWEEN 180-220 CYCLES. MECHANIC: C/W ONE TIME INSP PER ERA 620571-14 REV ORIG SECT IV. NO FURTHER DAMAGE NOTED. OKAY TO CLOSE MONITOR. REFER TO LOG #6593489 FOR MON TRACKING OF SECT V AT 420 CYCLES. CLOSED LOG AND REMOVED MONITOR INSP PER ALERT 04DEC24 AND LOG COMMENTS. (LP #9980685)

More about the Boeing 717-200