What was found
CRACK ON RIGHT ENG BYPASS DUCT NEAR PRECOOLER INLET WAS TEMPORARILY REPAIRED. RE-INSPECTION REQUIRED PER ER/A 620571-14 REV ORIGINAL. REFER TO LOG #0580374 FOR PRIOR INSPECTION. SECTION 4 INSPECTION MUST BE ACCOMPLISHED BETWEEN 220 AND 180 FLIGHT CYCLES PER ERA 620571-14 REV ORIGINAL. **REDEFERRED LOG TO QC, ESTAB MON INSP BETWEEN 180-220 CYCLES. MECHANIC: C/W ONE TIME INSP PER ERA 620571-14 REV ORIG SECT IV. NO FURTHER DAMAGE NOTED. OKAY TO CLOSE MONITOR. REFER TO LOG #6593489 FOR MON TRACKING OF SECT V AT 420 CYCLES. CLOSED LOG AND REMOVED MONITOR INSP PER ALERT 04DEC24 AND LOG COMMENTS. (LP #9980685)