Service difficulty report · Bleed Air Sys · Airbus BD5001A10

Difficulty date
December 6, 2024
Submitted
December 10, 2024
Operation
Air carrier
Aircraft
N123DQ
Make and model
Airbus BD5001A10
Aircraft serial
50042
Aircraft time
13,578 hours, 6,201 cycles
Part
Bleed Air Sys
Condition
Odor
Location
Zone 100
Stage of operation
AP
How discovered
O
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FUME /DIRTY SOCK SMELL ON T/O DISSIPATED QUICKLY RETURNED ON FINAL APPROACH. PERFORMED A220 NO GO ODI PREVENTION ATA 2172-SMOKE /FUMES IN THE CABIN PERFORMED STEP 1 :AMDS WORKCARD 0550-2001 STILL REQUIRES STEP 12 TO BE COMPLETED .FOUND SOURCE OF SMELL COMING FROM LEFT ENG BLEED SOURCE. PERFORMED AMDS WORKCARD 0550-6001UP TO STEP 6B. (JR 856279). C/W W/C 0550-6001 REPAIR ENG SOURCE. C/W W/C 0550-2001 ISOLATE SMOKE AND FUMES AND C/W W/C ECS DECONTAMINATION POST SMOKE AND FUME. ALL WORK CARDS COMPLETED. NO FURTHER DEFECTS NOTED. A/C OK FOR SVC. (LP# 6562826)