Service difficulty report · Wire · Boeing 717200

Difficulty date
December 14, 2024
Submitted
December 16, 2024
Operation
Air carrier
Aircraft
N943AT
Make and model
Boeing 717200
Aircraft serial
55006
Aircraft time
65,377 hours, 46,864 cycles
Part
Wire
Condition
Shorted
Location
Zone 200
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

THE FWD EXIT SIGN OVER FWD F/A SEAT IS INOPERATIVE. ALSO, 4 EXIT LIGHTS ON AFT CATWALK ARE INOPERATIVE. MAINTENANCE REPLACED THE FWD EMERGENCY EXIT SIGN (L2-790). ALL LIGHTS ASSOCIATED WITH BATTERY PACK B5-260 ARE INOPERATIVE. MAINTENANCE REPLACED THE BATTERY PACK PER B717 AMM 33-51. PAX CABIN EEPL CHECK OK. AFT ACCESSORY COMPARTMENT EEPL REMAIN INOPERATIVE. FOUND NO POWER COMING FROM PLUG P1-260 PIN 9 TO TERMINAL BLOCK S3-559 STUD 1. FOUND WIRE SHORT ON WIRE E9405-519-16 BETWEEN PLUG P1-6028 AND SPLICE P1-3803. REPAIRED WIRE C9302-255-16 PER B717 SWPM 20-10. REPLACED EMERGENCY POWER SUPPLY PER B717 AMM 33-51. REPLACED CATWALK LIGHT L2-845 AND CONNECTORS. REPLACED CONNECTORS P1/R5-3804, P1/R5-3803, P1/R5-3805, AND P1/R5-3806 AS WELL PER B717 WDM 33-51-14. ALL EEPL CHECK GOOD. (LP #6621480)