What was found
CRACK ON INNER PAN AT FWD EDGE BTW BEAM 1 AND 2 WAS FOUND ON AFT CARGO DOOR. SUMMARY OF NRC 00442: OUTER PAN FWD EDGE BTW BEAM 1 AND 2 WAS BLENDED OUT AND MEASURED AS FOLLOW: MINIOR DAMAGED TO SKIN EDGE NO MORE THAN 0.380" DEEP: BLEND OUT IS 0.125". REWORK AREA NO LONGER THAN 1.250": REWORK IS 1.000". THEREFORE, IS WITHIN LIMITS PER B717-200 SRM 51-70-01-2R REPAIR 2. INNER PAN AT FWD EDGE BTW BEAM 1 AND 2 AT AFT CARGO DOOR WAS REPAIRED PER B717-200 SRM 52-30-02-2R REPAIR 8. (LP #0719118)