What was found
CORROSION ON FLOOR SUPPORTS (3 EA), FROM STA Y=1022 TO STA Y=1063 ON X=44, X=52, AND X=-44 AT AFT PAX CABIN FLOOR. SUMMARY OF NRC 00459: CORROSION LEVEL 2. FLOOR SUPPORTS (3 EA), FROM STA Y=1022 TO STA Y=1063 ON X=44, X=52, AND X=-44 AT AFT PAX CABIN FLOOR WERE REPLACED DUE TO CORROSION OUT OF LIMITS PER B717-200 SRM 51-41-01-0G, 51-41-05-0G, AND DWG 5940155 REV J. (LP #0736586)