What was found
AICRAFT 3736, CORROSION ON TERMINATION FITTING AT STR23L STA1006+8" WL195. CORRECTIVE ACTION: EVALUATED DAMAGE ON TERMINATION FITTING AT STR 23L STA 1006+8" WL 195, FOUND TO BE OUT OF LIMITS DUE TO EXCESSIVE CORROSION PER B737 SRM 51-10-02, PARA. 9.C REMOVED AND REPLACED FITTING PER B737 SRM 51-40-02, AMM 20-50-11-910-801 DWG# 148A0933 REV. E. (LP 0738572)