What was found
RH SLAT TRACK NBR 4 PINION TEETH (2EA) HAS EVIDENCE OF CORROSION REF 5742-01028-02B. LIAISON ENGINEERING SUPPORT WILL BE REQUIRED BEFORE FURTHER FLIGHT. C/W PRI 624075-14AD TO STEP 6. T. FREE 1643853. PERFORMED EDDY CURRENT INSPECTION PER ERA 624075-14AD PRI REV O STEP 7 WITH REFERENCE TO ANDTP BD500-A-J51-01-20-01AAA-353A-A. NO DEFECTS NOTED. QC5220 750016. C/W ERA 624075-14AD REV O AND PRI 624075- 14AD REV O MATCHES. (LP# 0794933)