What was found
(LOG 0808942) WHILE IN QRO FOR MTC, AN INTERNAL DOUBLER IS LOCATED IN THE MFEC AREA (SEE WORK CARD 5330-2575) OF THE ICA FOR THE GOGO WIFI INSTALLATION AREA (AA 2330-01344) AND THE MFEC CANNOT BE ACCOMPLISHED. THE EDGE OF THE DOUBLER EXTENDS UP ONTO THE CHEM-MILLED STEP AND THE RESULTING GAPS ARE UN-SHIMMED. REPAIRED AREA PER ERA 623902-1