What was found
OUT OF LIMIT INNER DIAMETER DIMENSION ON FIXED BUSHING OUTBOARD LUG HINGE N5 AT RH ELEVATOR. REPAIRED BORE AND REPLACED BUSHING (1 EA) ON HINGE FITTING #5 O/ B LUG AT RH ELEVATOR AS PER A319 SRM 55-26-41-300-004. (LP: 0828552)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
OUT OF LIMIT INNER DIAMETER DIMENSION ON FIXED BUSHING OUTBOARD LUG HINGE N5 AT RH ELEVATOR. REPAIRED BORE AND REPLACED BUSHING (1 EA) ON HINGE FITTING #5 O/ B LUG AT RH ELEVATOR AS PER A319 SRM 55-26-41-300-004. (LP: 0828552)