What was found
CORROSION OUT OF LIMITS, IN REF TO NRC 0642: CORROSION ON RH CUSP WEB STA Y=389, ORIGINAL THICKNESS OF 0.020 IN AND MINIMUM REMAINING THICKNESS IS 0.010 IN, PER B717-200 SRM 53-00-55-1A-1 PROCEDURE 1 ALLOWABLE DAMAGE 1 PAR. 4. A. FIG. 101. SUMMARY OF NRC 00830: CORROSION LEVEL 2. THE RH CUSP WEB STA Y=389 WAS REPAIRED PER B717-200 SRM 53-00-55-2R REPAIR 4 FIG 219. (LP #0841359)