What was found
CORROSION ON END-LONGERON BTW STA 1002 LONGERON 27RH AT AFT CARGO COMPARTMENT. SUMMARY OF THE NRC 00284: CORROSION LEVEL 2. END-LONGERON BTW STA 1002 LONGERON 27RH AT AFT CARGO COMPARTMENT WAS REPLACED PER B717-200 SRM 51-41-05-0G. (UT) THICKNESS MEASURED WAS ACCOMPLISHED AFTER REWORKED AREA ON END-LONGERON BTW STA=994 LONGERON 27RH AT AFT CARGO COMPARTMENT. ORIGINAL THICKNESS IS 0.063IN MINIMUM REMAINING THICKNESS IS 0.010IN THEREFORE AREAS IT IS OUT LIMITS PER B717-200 SRM 53-00-00-1A PROCEDURE ALLOWABLE DAMAGE GENERAL PAR 4 C (2) FIG 103 AND DC-MD/BOEING NDT SPM PART. 4,04 -00-06 PAR 4. FIG 9. PERFORM VISUAL INSPECTION ON NEXT SERVICE PER B717-200 SRM 53-00-00-1A PAR 5 TABLE 101. (LP #0874825)