What was found
-AD- DAMAGE TOLERANCE EVALUATION, ER/A 622334-14 SECT II WITH AMOC TO AD 2024-21-01. DTA MONITOR INSPECTION REQUIRES DTA / AMOC APPROVAL BEFORE THE 1ST OF 30 DAYS OR 177 CYCLES. CONTACT MSP LIAISON ENGINEERING. DISCONTINUE REVENUE SERVICE ON OR BEFORE 30 DAYS OR 177 CYCLES PENDING A DAMAGE TOLERANCE AND FATIGUE REVIEW WITH AMOC. ASSOCIATED AA 5720-01103 ADDED FOR AC 9544. ASSOCIATED ER/A 00-622334 ADDED FOR AC 9544. **REDEFERRED LOG TO QC, ESTAB MON INSP** 10-0557-8-9588 COMPLIED WITH ER/A 622334-14AD REV A. REFER TO LOG #0872418 FOR ER/A 622334-14AD REV A REPETITIVE INSPECTIONS. CLOSED LOG AND REMOVED MONITOR INSPECTION. (LP #0822756)