What was found
DUE TO CORRISION REWORK, (UT) THICKNESS MEASUREMENT WAS ACCOMPLISHED ON SIDE TIE TRACK BTW L27L TO L28L AND STA=900 LH TO STA=1022 LH AFT CARGO COMPARTMENT. WITH AN ORIGINAL THICKNESS OF 0.060IN, AND MINIMUN REMAINING THICKNESS OF 0.027IN. THE AREA REWORKED IS OUT OF LIMITS. SUMMARY OF NRC 00690: CORROSION LEVEL 2. NEW SIDE TIE TRACK WAS FABRICATED PER DGW 5936663-547 REV Y AND REPLACED PER B717-200 SRM 51-41-01-0G. (LP #0901443)