As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SHIP 3142 CORROSION FLOOR BEAM +Y1162.5 LOCATED BTW FR 68 TO FR 69 AT AFT GALLEY AREA (SSI 534147). REPLACED FLOOR BEAM Y1162.5 LOCATED BTW FR 68 TO FR 69 AT AFT GALLEY AREA ASPER A319 SRM 51-72-11, A319 SRM 51-42-11 AND DWGD53472780 RELEASE DATE: 26-APR-18 ISSUE K AND DWG D53474250 RELEASE DATE 11-FEB-04 ISSUE V. MEASURE OF CORROSION ARE: L= 0.105IN W= 0.100 IN D=0.025 IN